COENG 50-300kW Modular Bidirectional PCS Power Conversion System for Microgrids
Key Attributes
Modular Bidirectional PCS
,50-300kW PCS for Microgrids
,Bidirectional Power Conversion System
The COENG 50–300kW Modular Bidirectional Power Conversion System (PCS) delivers flexible, scalable energy conversion for commercial and industrial energy storage. Built for seamless integration with photovoltaic storage systems, it supports both grid-tied and off-grid operation, making it a reliable core component for microgrids and battery energy storage applications.
- Modular energy storage inverter platform scalable from 50kW to 300kW
- Bidirectional power conversion for battery charging and discharging
- Compatible with lithium, lead-acid batteries and solar panel (MPPT) input
- Grid-tied and off-grid operating modes with high efficiency up to 98.5%
- Indoor IP21 and outdoor IP55 protection options
| Model | 50kW | 100kW | 150kW | 200kW | 250kW | 300kW |
|---|---|---|---|---|---|---|
| Operating voltage range | 500~1000V | |||||
| Full load voltage range | 600~950V | |||||
| Max. DC current | 100 | 200 | 300 | 400 | 500 | 600 |
| Input quantity | 1 | 1/2 | 1/3 | 1/2/4 | 1/5 | 1/3/6 |
| Adaptive battery | Lithium / lead acid / solar panel (MPPT) | |||||
| Parameter | 50kW | 100kW | 150kW | 200kW | 250kW | 300kW |
|---|---|---|---|---|---|---|
| Rated AC power | 50kW | 100kW | 150kW | 200kW | 250kW | 300kW |
| Max. AC power | 55kVA | 110kVA | 165kVA | 220kVA | 275kVA | 330kVA |
| Rated AC current | 72A | 144A | 216A | 288A | 361A | 432A |
| Rated AC voltage | 400Vac (-20%~+15%), 3W+N+PE | |||||
| Rated frequency | 50/60Hz (±5Hz) | |||||
| THDi | <3% (rated power) | |||||
| PF adjustable range | -1 (leading)~+1 (lagging) | |||||
| Parameter | Specification |
|---|---|
| Rated AC voltage | 400Vac, 50/60Hz |
| THDv | <3% (linear load) |
| Unbalanced load capability | 100% |
| Overload capacity | 110%: long-term working; 120%: 1 minute |
| Isolation mode | Non-isolation (transformer optional) |
| Parameter | 50kW | 100kW | 150kW | 200kW | 250kW | 300kW |
|---|---|---|---|---|---|---|
| Maximum efficiency | 98.1% | 98.2% | 98.3% | 98.4% | 98.5% | 98.5% |
| Weight (approx.) | 200kg | 240kg | 280kg | 320kg | 360kg | 400kg |
| Dimension | 800×800×2100mm; 800×800×2100mm (built-in transformer); 1200×800×2100mm (built-in transformer) | |||||
| Parameter | Specification |
|---|---|
| Protection level | Indoor: IP21; Outdoor: IP55 |
| Operating temperature | -25~60℃ (derating above 45℃) |
| Altitude | 3000m (>3000m derating) |
| Communication interface | RS485 / CAN 2.0 / Ethernet / Dry Contact |
EN 61000-6-1 / EN 61000-6-2 / EN 61000-6-3, IEC 61000, IEC 62477-1:2012, IEC 61727, IEC 62116, GB/T 34120, GB/T 34133