2kw Lithium Battery Making Machine 100V 20A Charge And 40A Discharge Machine
Key Attributes
2kw lithium battery making machine
,100V 20A battery charge machine
,40A discharge battery production machine
Product characteristics:
♦ The voltage can be set at a maximum of 10-100V, charging current 0-20A, discharge current 0-40A
♦ At the same time, aging positive plate can protect negative plate discharge protection
♦ By charging and discharge cycle of the battery, you can detect whether the charging protection and discharge protection of the battery are normal
♦ Charge and discharge cycle on the battery and record the charging capacity and discharge capacity
♦ The equipment has anti-reverse protection function. The device number is displayed through LED lamp, and the corresponding number can be inquired at any time
♦ The instrument provides P + and P-interfaces, and CH + and CH-, can test special finished batteries
♦ The equipment has a safe discharge current protection function
♦ PC computers can be connected through the serial port to reduce the complexity of instrument use
♦ Network connection mode can be adopted, and the PC computer terminal can control within 254 instruments by only providing one network port
♦ The software system adopts a classic and mature C/S mode
♦ Communication modes have serial port and network mode equipment with voltage upper and lower limit setting protection
♦ The serial port can realize the accurate communication of several instruments for short distances
♦ The network can achieve long-distance multiple instrument preparation communication
♦ The device can view the charge and discharge aging curve and export the curve diagram
♦ In network mode, automatic online, no manual online
| Input Power | AC 380V 2kw 50/60Hz | |
| Voltage | Measuring range | 10~100V |
| Precision | ±(0.2% of reading + 0.2% of range) | |
| Electric Current | Charging range | 2~20A |
| Charging accuracy | ±(0.2% of reading + 0.2% of range) | |
| Discharge range | 2~40A | |
| Precision | ±(0.2% of reading + 0.2% of range) | |
| Charging | Constant voltage cut-off current | (minimum)10mA |
| Capacity | Precision | ±1‰ |
| Power | Discharge power | 4000W |
| Time | Inspection time | <2S(Receive real-time & LT; 2s) |
| Timing range | 0 ~ 999 hours / Step | |
| Data recording interval | ≥5S | |
| Median version | 1.1 series | |
| Charging | Charging mode | Constant current and constant voltage charging |
| Cut-off condition | Voltage, current, relative time, overcharge protection | |
| Discharge | Discharge mode | Constant current discharge |
| Cut-off condition | Voltage, relative time, over-discharge protection | |
| Circulates | Cyclic range | 1~999 |
| Single cycle number of steps | 100 | |
| Voltage and current detection sampling | Four wire connection | |
| Noise | <50dB | |
| Database | Using My SQL database to manage test data | |
| Communication Mode of upper computer | Based on TCP / IP Protocol, serial port | |
| Data output mode | EXCEL,TXT,Chart | |
| Communication interface | Mesh opening | |
| Number of channels per cabinet | Single Channel | |
| Case size | W*D*H:800MM*520MM*1370MM | |
| Cabinet size | W*D*H:700MM*400MM*420MM | |