2kw Lithium Battery Making Machine 100V 20A Charge And 40A Discharge Machine
2kw Lithium Battery Making Machine 100V 20A Charge And 40A Discharge Machine
Key Attributes
Product Attributes
Highlight
2kw lithium battery making machine
,100V 20A battery charge machine
,40A discharge battery production machine
Product Description
2kW Lithium Battery Making Machine 100V 20A Charge and 40A Discharge Machine
Product Characteristics
- Voltage range: 10-100V maximum setting capability
- Charging current: 0-20A, Discharge current: 0-40A
- Simultaneous aging positive plate with negative plate discharge protection
- Battery charge and discharge cycle testing for protection functionality verification
- Records charging capacity and discharge capacity during cycles
- Anti-reverse protection function with LED display for device identification
- P+ and P- interfaces, CH+ and CH- interfaces for special finished battery testing
- Safe discharge current protection function
- PC connectivity via serial port for simplified operation
- Network connection supporting control of up to 254 instruments through single network port
- Classic C/S mode software system
- Serial port and network communication modes with voltage limit protection
- View and export charge/discharge aging curves
- Automatic online functionality in network mode
Technical Specifications
| Parameter | Specification |
|---|---|
| Input Power | AC 380V 2kW 50/60Hz |
| Voltage | Measuring range: 10-100V Precision: ±(0.2% of reading + 0.2% of range) |
| Electric Current | Charging range: 2-20A Charging accuracy: ±(0.2% of reading + 0.2% of range) Discharge range: 2-40A Precision: ±(0.2% of reading + 0.2% of range) |
| Charging | Constant voltage cut-off current: (minimum) 10mA |
| Capacity Precision | ±1‰ |
| Discharge Power | 4000W |
| Inspection Time | <2S (Receive real-time < 2s) |
| Timing Range | 0 - 999 hours / Step |
| Data Recording Interval | ≥5S |
| Median Version | 1.1 series |
| Charging Mode | Constant current and constant voltage charging |
| Charging Cut-off Conditions | Voltage, current, relative time, overcharge protection |
| Discharge Mode | Constant current discharge |
| Discharge Cut-off Conditions | Voltage, relative time, over-discharge protection |
| Cycle Range | 1-999 |
| Single Cycle Steps | 100 |
| Voltage/Current Detection | Four wire connection |
| Noise | <50dB |
| Database | MySQL database for test data management |
| Communication Interface | Mesh opening |
| Channels per Cabinet | Single Channel |
| Case Size | W×D×H: 800mm × 520mm × 1370mm |
| Cabinet Size | W×D×H: 700mm × 400mm × 420mm |
Data Communication & Output
- Upper computer communication: TCP/IP Protocol and serial port
- Data output formats: EXCEL, TXT, Chart
- Serial port enables accurate short-distance communication for multiple instruments
- Network enables long-distance multiple instrument preparation communication
Request A Quote