100V 7-Channel Battery Pack Aging Machine
Key Attributes
100V battery pack aging machine
,7-channel battery aging equipment
,lithium battery pack production line
COENG's 100V battery pack aging machine is a seven-channel charge-discharge tester built for lithium-ion battery pack production. With 0–10A charging, 0–20A discharging and a specified discharge power of ≤1400W, it supports capacity measurement and charging/discharging protection checks for packs matched to its operating limits.
This programmable battery pack tester combines CC/CV charging with constant-current discharge. Test recipes support up to 100 steps per cycle and 1–999 cycles, with voltage, current, time and protection-related cut-off settings as applicable to each mode. Four-wire voltage and current detection supports reliable battery pack evaluation.
PC software provides TCP/IP and serial communication, with MySQL data management and EXCEL, TXT and chart outputs. The 900 × 600 × 1900 mm cabinet contains seven channels and is specified for AC 380V, 7kW input. A USB concentrator and router are included according to the supplied equipment information.
For equipment importers, battery pack manufacturers and production-line integrators, this battery pack test station supports assembly quality control. Send your full-charge voltage, pack capacity, required test current and daily throughput to request a configuration review and quotation.
- Seven-channel cabinet: A floor-standing configuration for battery pack production testing.
- Defined test ranges: 0–100V voltage measurement, 0–10A charging and 0–20A discharging, with a specified discharge-power limit of ≤1400W.
- Programmable recipes: Up to 100 steps per cycle and 1–999 cycles for repeatable test procedures.
- Charge and discharge assessment: CC/CV charging, constant-current discharge, capacity measurement and protection cut-off checks.
- PC data management: TCP/IP and serial communication, MySQL storage and EXCEL, TXT and chart outputs.
| Parameter | Specification |
|---|---|
| Voltage measurement range | 0–100V |
| Charging current range | 0–10A |
| Discharging current range | 0–20A |
| Specified discharge power | ≤1400W |
| Channels per cabinet | 7 |
| Charging mode | Constant current / constant voltage (CC/CV) |
| Discharging mode | Constant current (CC) |
| Voltage accuracy | ±(0.2% of reading + 0.2% of range) |
| Charging current accuracy | ±(0.2% of reading + 0.2% of range) |
| Discharging current accuracy | ±(0.2% of reading + 0.2% of range) |
| Minimum CV cut-off current | 10mA |
| Cycle setting range | 1–999 cycles |
| Steps per cycle | 100 |
| Timing range | 0–999 hours per step |
| Data recording interval | ≥5 seconds |
| Voltage and current detection | Four-wire connection |
| Charging cut-off conditions | Voltage, current, relative time and overcharge protection |
| Discharging cut-off conditions | Voltage, relative time and over-discharge protection |
| PC communication | TCP/IP and serial port; RS232 described in equipment overview |
| Data management | MySQL database |
| Data outputs | EXCEL, TXT and charts |
| Included system items | PC software, USB concentrator and router |
| Input power | AC 380V, 7kW |
| Cabinet dimensions (W × D × H) | 900 × 600 × 1900mm |
| Case dimensions (W × D × H) | 450 × 300 × 170mm |
Important: The listed voltage, current and power limits must be evaluated together. Confirm the operating envelope and whether the quoted discharge-power rating applies per channel or per cabinet before defining the test recipe. Pack full-charge voltage must be checked rather than relying only on nominal voltage.
It performs controlled charging and discharging to measure battery pack capacity and check charging and discharging protection cut-off behavior.
Compare the pack's full-charge voltage and required test currents with the equipment's complete voltage, current and power operating limits. Confirm the usable voltage range, connector arrangement and protection settings with the technical team.
The supplied specifications list constant-current / constant-voltage charging and constant-current discharging, with mode-specific cut-off conditions.
The supplied information lists EXCEL, TXT and chart outputs, with a MySQL database for data management.
The cabinet is specified with seven channels. Confirm channel control, fixture requirements and the intended test recipe when planning production capacity.
Provide battery chemistry, full-charge voltage, capacity, charge/discharge current, test duration, daily production volume, required channel count, installation power supply and destination country.





-
RWe chose the COENG glove box for a battery materials development workspace requiring controlled-atmosphere handling and frequent transfers of small samples and laboratory tools. The large antechamber with its sliding tray, together with a separate small antechamber, was particularly relevant to our workflow. Penny worked through our material list, solvent use and utility requirements with us. We also discussed the regeneration function and the solvent adsorption module with its 7 kg activated carbon charge. Her explanation of the configuration and the items requiring technical confirmation helped us prepare a clearer installation and acceptance plan.
-
AOur project involved sourcing equipment for a university battery research laboratory. We needed a single-station glove box with gas purification, water and oxygen monitoring, and an English-language control interface. Penny coordinated the technical discussions and helped us compare the proposed configuration with the laboratory’s purchasing requirements. We reviewed the 2020 × 850 × 1900 mm overall dimensions for installation planning and checked the transfer chambers against the intended sample sizes. The COENG configuration brought the workspace, monitoring and purification functions together in one equipment package, making it easier to define our procurement scope.
-
MWe selected the COENG glove box for a laboratory project involving moisture-sensitive battery materials and small-scale cell assembly. Our purchasing priorities were controlled water and oxygen levels, accessible working space and practical sample transfer. Penny helped us review the chamber dimensions, antechamber sizes and gas supply requirements against our planned workflow. She also clarified the conditions associated with the specified below-1-ppm water and oxygen acceptance levels. The stainless steel workspace, internal shelving and dual antechambers matched the configuration we were seeking for our research station.